be_ixf;ym_202412 d_23; ct_50

Air Pilot Actuator Selection

Category: 
    MPA series air pilot actuators attach to the top of our miniature 2-Way, 3-Way, and 4-Way valves and electric switches via a #15/32-32 mounting thread to provide pressure pilot actuation from a pneumatic signal.
   
Minimum Pilot Pressure Required to Shift Valve
Clippard Valve Series MPA-3 MPA-5 MPA-7 MPA-10 MVA-10
SAS, MAS Switches 12 psig 4 psig 2 psig n/a n/a
FV-3, FV-4, FV-5 Series 41 psig 15 psig 7.5 psig 4.0 psig 8.2" Hg
FV-3D, FV-4D, FV-5D Series 14 psig 5 psig 2.5 psig 1.5 psig 3.2" Hg
MAV-2, MAV-3 Series 23 psig 8 psig 4 psig 2 psig 4.2" Hg
MAV-4, MJV-4 Series 36 psig 11 psig 5.5 psig 3.5 psig 7.2" Hg
MAV-4D, MJV-4D Series 13 psig 4 psig 1.5 psig 1 psig 2" Hg
MJV-2, MJV-3 Series 30 psig 10 psig 5 psig 3 psig 6.2" Hg
MAVO-2, MAVO-3 Series 27 psig 9 psig 4.5 psig 2.5 psig 5.2" Hg
MJVO-2, MJVO-3 Series 30 psig 10 psig 5 psig 3 psig 6.2" Hg
GV Series 87 psig 31 psig 16 psig 8 psig 16" Hg
HV-4 Series 41 psig 15 psig 7.5 psig 4.0 psig 8.2" Hg

All data is tested using 100 psi on the valves supply port.  Different line pressures to the valve may result in different minimum pilot pressures required to shift the valve.