Clippard EVP Proportional Valves Selection Tips
... on these three: Control Signal , Valve Orifice and Operating Pressure . If you can't find the right configuration ... Valve can be calibrated for pressures less than the maximum pressure shown above. Lower pressures may be substituted in increments ...
-
Pneumatic Glossary of Terms
... Air, Dried . Air with moisture content lower than the maximum allowed for a given application. Air, Free. Air at ambient ... element such as a piston and a piston rod, plunger or ram, operating within a cylindrical bore. D Desiccant. Material ...
-
New! Cordis Electronic Flow Controller
... Operating Flow Range Minimum: 0 to 15 sccm Maximum: 0 to 6 l/min ...
-
Digital vs. Analog Control in Proportional Applications
... will be the time required for the controller to achieve the maximum power output to the valves in response to a change in command or operating conditions. Generally speaking, an analog controller will react to ...
-
Cordis CPC Electronic Pressure Controls FAQ
... unit? A: Inlet pressure needs to be 10% higher than the maximum calibrated range of your Cordis. Refer to the Operating Instructions for max. inlet pressure per calibrated range. Is ...
-
Clippard Push/Pull Valves Press Release
... the flexibility for unlimited applications. And, with an operating temperature of 32 to 140°F and an operating pressure of 0 to 115 psig, these new valves offer top notch performance where maximum performance and maximum value are demanded. For complete details or ...
-
Clippard Push-Pull Valves
... the flexibility for unlimited applications. And, with an operating temperature of 32 to 140°F and an operating pressure of 0 to 115 psig, these new valves offer top notch performance where maximum performance and maximum value are demanded. Ports: 1/4" NPT, 1/8" ...
-
Clippard Heavy-Duty Limit Valves Instructions
... to resist corrosion. Used in the limit valve, the maximum flow (2-way or 3-way) is 540 l/min at 100 psig and 280 l/min at 50 psig. Pressure range is 0 to 300 psig. Model Cartridge Valve ... solenoid valves in pneumatic circuits. They have the same operating characteristics as other types of limit switches, but provide ...
-
Resolution in Proportional Control
... valve operation and setup: downstream volume, minimum and maximum inlet pressures, media, operating and ambient temperatures, minimum and maximum flow requirements, and ...
-
Stability vs. Fill-Time in Proportional Control Applications
... in a process and be tuned correctly for the particular operating conditions. Stability The perfect electronic proportional ... the smallest restriction in the process dictates the maximum possible flow rate. For example, basketball manufacturers are ...