Is the output flow of the Cordis Flow Controller linear?
A: Yes, within +/- 1% FS
How can I electronically control the Cordis?
A: The Cordis Flow Controller can be commanded by using voltage, serial or current command.
Are there other plumbing options available?
A: The Cordis is available in 1/8" NPT or G1/8. (Manifold mount for specials only).
Can PID changes be made in the field?
A: Yes. Refer to the Operations Manual for command sets needed to accomplish this.
Can Cordis be calibrated 0 to 5.00 VDC instead of 0 to 10.00 VDC?
A: Yes, but under a special part number.
Can the output flow of the Cordis be customized?
A: Yes, This would require more detailed application specifications and a custom part number.
Can the output flow of the Cordis be customized?
A: Yes. This would require more application details and a custom part number.
What is the lowest full scale calibrated range of the Cordis?
A: 0 to 15 sccm full scale is available with a custom part number.
Where can the Cordis be purchased?
A: On-line or from your local Clippard Distributor
Does the Cordis Flow Controller require a constant regulated pressure to function accurately?
A: To maintain accuracy specifications, supply pressure must remain within 10 psig of the range identified within the configured part number.
Is the housed Cordis Flow Controller IP65?
A: Yes
Are there mounting brackets available?
A: No
What is the resolution of the Cordis Flow Controller?
A: The Controller can respond to command signal changes as low as 25 mV.
Can the Cordis Controller work with vacuum?
A: Yes, but requires a custom part number.
Will the Cordis unit be capable of performing at higher flows above 6 l/min.?
A: Yes, Special Orders and application specific details required to establish a custom part number/configuration.
Can the calibrated output range be inverted?
A: Yes, as a special.
Can the Cordis Flow Controller be used with water type media?
A: No. Clean, dry, inert gases only.